dc.contributor.author | Asav, Engin | |
dc.contributor.author | Sağıroğlu, Ayten | |
dc.contributor.author | Sezgintürk, Mustafa Kemal | |
dc.date.accessioned | 2021-12-12T17:00:45Z | |
dc.date.available | 2021-12-12T17:00:45Z | |
dc.date.issued | 2016 | |
dc.identifier.issn | 1040-0397 | |
dc.identifier.issn | 1521-4109 | |
dc.identifier.uri | https://doi.org/10.1002/elan.201500324 | |
dc.identifier.uri | https://hdl.handle.net/20.500.11857/2885 | |
dc.description.abstract | Calretinin (CAL) is calcium binding protein, and its levels in blood and cerebrospinal fluids are increased, since its expression is increased various cancer types. A novel biosensor system fabricated by immobilization of a specific antibody to CAL, anti-Calretinin (anti-CAL), onto a gold electrode surface via an effective covalent binding method using mercaptohexanol, epichlorohydrin, and ethanolamine was reported for the sensitive, selective, and accurate analysis of CAL. The proposed biosensor showed a linear calibration range between 1 ng/mL and 5 ng/mL. LOD and LOQ values were determined as 0.11 ng/mL and 0.38 ng/mL, respectively. The standard deviation related to the reproducibility of the new biosensor system was calculated as 3.95%. Lastly, in order to state the applicability of the biosensor to early diagnosis of CAL in practice, artificial serum samples spiked with CAL have been analyzed by the proposed biosensor. | en_US |
dc.description.sponsorship | TUBITAK (The Scientific and Technological Research Council of Turkey)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [113Z 678] | en_US |
dc.description.sponsorship | This work was funded by TUBITAK (The Scientific and Technological Research Council of Turkey, Project numbers: 113Z 678). | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Wiley-V C H Verlag Gmbh | en_US |
dc.relation.ispartof | Electroanalysis | en_US |
dc.identifier.doi | 10.1002/elan.201500324 | |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Calretinin | en_US |
dc.subject | epichlorohydrin | en_US |
dc.subject | cancer biomarker | en_US |
dc.subject | immunosensor | en_US |
dc.subject | Electrochemical Impedance Spectroscopy | en_US |
dc.title | Quantitative Analysis of a Promising Cancer Biomarker, Calretinin, by a Biosensing System Based on Simple and Effective Immobilization Process | en_US |
dc.type | article | |
dc.authorid | Asav, Engin/0000-0002-6232-3388 | |
dc.department | Fakülteler, Sağlık Bilimleri Fakültesi, Beslenme ve Diyetetik Bölümü | |
dc.identifier.volume | 28 | en_US |
dc.identifier.startpage | 334 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.endpage | 342 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.authorscopusid | 25935968900 | |
dc.authorscopusid | 6603077608 | |
dc.authorscopusid | 6506764918 | |
dc.identifier.wos | WOS:000370138000011 | en_US |
dc.identifier.scopus | 2-s2.0-84963657222 | en_US |
dc.authorwosid | Asav, Engin/AAG-4182-2021 | |
dc.authorwosid | Asav, Engin/AAG-1170-2021 | |
dc.authorwosid | Sezginturk, Mustafa Kemal/AAY-1439-2021 | |