Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÖzcan, Cemile
dc.contributor.authorAközcan, Serpil
dc.date.accessioned2021-12-12T17:01:11Z
dc.date.available2021-12-12T17:01:11Z
dc.date.issued2020
dc.identifier.issn1944-3994
dc.identifier.issn1944-3986
dc.identifier.urihttps://doi.org/10.5004/dwt.2020.24900
dc.identifier.urihttps://hdl.handle.net/20.500.11857/3103
dc.description.abstractThe purpose of this study was to determine the level after preconcentration of trace heavy metals ions using drinking fountain water (20 points) in Kirklareli province by flame atomic absorption spectrophotometer. The method is based on the adsorption of nickel(Ni), lead(Pb) and cadmium(Cd) on quercetin loaded on granular activated carbon. In this study, the effectiveness of variabilities including solution pH, the amount of the ligand and solid phase, the condition of eluting solutions and sample volume on the recoveries of metals were optimized. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation (RSD%) of Ni, Pb, and Cd were investigated. RSDs were found below 5%. Further, the accuracy of the proposed method was also checked by the analysis of certified reference material NIST-SRM-1643e. Eventually, the recommended method was successfully implemented for the analysis of the Ni, Pb, and Cd in environmental water samples. The concentrations of Pb, Ni, and Cd in the waters ranged from 11.0 to 187 mu g L-1 for Pb, 14.3 to 56.8 mu g L-1 for Ni and 1.21 to 8.90 mu g L-1 for Cd.en_US
dc.description.sponsorshipKirklareli University Research Foundation [KLUBAP/011]en_US
dc.description.sponsorshipThe authors thank the Kirklareli University Research Foundation for their support (KLUBAP/011).en_US
dc.language.isoengen_US
dc.publisherDesalination Publen_US
dc.relation.ispartofDesalination and Water Treatmenten_US
dc.identifier.doi10.5004/dwt.2020.24900
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFlame atomic absorption spectrophotometer (FAAS)en_US
dc.subjectEnrichmenten_US
dc.subjectActivated carbonen_US
dc.subjectQuercetinen_US
dc.subjectSolid phase extractionen_US
dc.titleDetermination of Ni, Pb and Cd in drinking fountain water in Kirklareli/Turkey by FAAS after preconcentration on quercetin modified using granular activated carbonen_US
dc.typearticle
dc.departmentFakülteler, Fen-Edebiyat Fakültesi, Kimya Bölümü
dc.identifier.volume175en_US
dc.identifier.startpage219en_US
dc.identifier.endpage228en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid35365143800
dc.authorscopusid36482497000
dc.identifier.wosWOS:000544985400023en_US
dc.identifier.scopus2-s2.0-85089477290en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster